22 Ramp-Hold
Appendix A: Display Messages
Abort 5
The firing was stopped.
Alarm 8, 10, 11, 12
ALAR appears either when you are entering an alarm tem
-
perature or when the alarm is sounding during a firing. To
stop an alarm, press any key except STOP. If the alarm goes
off when you first begin firing, it is because it was set for a
lower temperature than the present temperature.
Auxiliary Output 8, 10, 16
The AOP option is for kilns equipped with a special-order kiln
switch box receptacle called the Auxiliary Output.
Bad Programming 20
This message appears when a firing has been programmed
with 0 rate in the first segment or when all target tempera
-
tures are lower than the current kiln temperature.
Configuration Code 18
This is an option that shows the factory configuration code
for your Sentry. This is for technicians who call the factory for
support.
Change °F / °C 15
Choose between operation in degrees F or degrees C.
Electrical Rate 12, 16
Enter the electric rate shown on your electric bill. Example:
10.25 cents per KWh is entered as 10.25.
Completed Firing 5, 9
This means the firing completed normally as programmed.
These three messages will also cycle one after the other:
firing time in hours and minutes, the temperature of the last
segment, and the current kiln temperature.
Delay 8, 11
DELA is a timer that starts the kiln later. Delay time appears
in hours and minutes.
or Target Temperature 6
This prompt is asking for a target temperature. The number
is the segment of the program.
Temperature Difference 14
This option shows the maximum temperature spread be
-
tween zones in a multiple-zone kiln.
Electronics Temperature 18
The Sentry circuit board is rated for operation at tempera
-
tures up to 176°F/80°C. When the circuit board gets hotter,
the Sentry shuts off. The ELEC option shows you the temper
-
ature of the circuit board.
Message Definition Page Reference
Electronics Too Hot 20
The Sentry circuit board is too hot, so the kiln shut off.
Thermocouple Failed 5, 20
The thermocouple failed. This can be due to a broken ther
-
mocouple, loose thermocouple connection on the back of
the controller, disconnected thermocouple wire, or a defec
-
tive controller.
Vent Fan 16
The Fan option, accessed through the OPTIONS key, is for
kilns equipped with a special-order kiln switch box recepta
-
cle called the Auxiliary Output.
Fan 8
If your kiln has the optional AOP outlet (for a kiln vent), the FN
prompt will appear for each segment during programming.
It is asking if you want the vent on or off for that segment.
Failed to Cool 17, 19
This error message means the kiln cannot cool as fast as the
cooling that you programmed.
Failed to Heat 17, 19
The kiln cannot heat as fast as you programmed.
Firing Too Long 20
The temperature rise is less than 27° /15°C per hour and the
firing time is two hours longer than the current segment was
programmed.
Full Speed 7, 8, 17
The rate, or temperature change per hour, is maximum.
Temperature Hold 8
When this message appears during programming, it is ask
-
ing you if you want to hold, or maintain, the target tempera
-
ture of that segment. If so, enter the length of hold time in
hours and minutes (Example: 1 hour 20 minutes = 01.20).
The number after Hd is the segment number. Each segment
in a firing is numbered.
High Temperature Deviation 17, 20
During a heating-up ramp or a hold, the temperature is
100°F / 56°C above the programmed temperature.
Computer ID 17
The ID option is for connecting the Sentry to a personal com
-
puter.
Ready to Begin 5
The Sentry must display the IdLE message before you can
begin firing or programming.
Message Definition Page Reference